The ARCHITECT i1000SR immunoassay analyzer meets your laboratory’s high standards by delivering STAT results when you need them. The system offers throughput of up to 100 tests per hour. ARCHITECT BNP RGT 500T(500T) Product Number 08K2835. MLTGNT CRP VRO(600T) Product Number 06K2630. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. Download Here: Abbott Architect 1000 Manual Printable 2019Abbott Architect 1000 Manual Printable 2019 is big ebook you want. You can read any ebooks you wanted like Abbott Architect 1000 Manual Printable 2019 in simple step and you can save it now. Or Free Reading at BRAZILFILMFESTIVAL.INFO Keywords: abbott, architect, 1000, manual, printable.
CONFIGURATION:
- 01 floor-standing module with the wheels, containing 4 primary components:
- System Control Center (SCC) including: 15-inch color LCD touch-screen monitor and universal keyboard that attached to the analyzer via an ergonomic, articulated arm, mouse and 01 built –in PC
- Robotic Sample Handler (RSH)
- Processing Center
- Supply and Waste Center
- 01 Standard Accessory kit
- 01 Printer
- 01 Application and Maintenance Manual
BENEFITS THANKS TO ADVANCED SCIENCE AND TECHNOLOGY
Multi-Dimensional Sampling (MDS) improves laboratory workflow
- Enhanced sample management flexibility with Robotic Sample Handler (RSH) that enables STAT, automated rerun, and reflex testing minimizes operator intervention
- 5-position carrier with spring-loaded fingers accommodates a vast majority of test tube types
- A variety of sample cups and false bottom tubes maintains barcode integrity for short/pediatric samples
- Intuitive indicator lights assist the operator in accessing sample status at a glance
- New Patented Wash Cup design and algorithm minimizes interferences, delivering confidence in results
- Clot detection utilizing pressure differential technology ensures accurate sampling
- Multiple sample loading of up to 65 samples via priority (configurable up to 35), routine areas with continuous sample access
Loading “on the flight” lifts the productivity of laboratory
- Continuous sample and reagent loading without pausing the analyzer
- Continuous unloading of the solid as well as liquid waste when the analyzer is running
CHEMIFLEXÒ Technology provides flexible protocols to optimize assay performance without compromising throughput
- CHEMIFLEX is Abbott’s unique combination of refined chemiluminescence detection technology with flexible assay protocols
- Refined chemiluminescence utilizes Abbott’s patented acridinium derivative that was specifically designed to improve reaction efficiency, reagent stability, and contribute to enhanced assay performance
- Flexible assay protocols allow assay development to use the protocol that provides the best assay performance and clinical accuracy
- Extended linear range reduces the need for dilutions and delivers excellent turnaround times.
- Impressive low-end performance ensures accuracy.
- Superior low-end sensitivity facilitates accurate diagnosis.
Industry leading software provides ease-of-use
- Touch-screen interface with icon-driven, intuitive screens provides software which is simple to learn and navigate
- Easy access for all functions minimizes hands-on time
- Online operation manuals, computer-based video training and access to screen-specific help provide convenient access to required information
- Online maintenance logs notify the operator when maintenance is due and automatically update when maintenance is performed
- A software design, which is common across all ARCHITECT systems, means less training and operator errors
COMMITMENT FROM THE VENDOR
- Abbott company is continuously updating ARCHITECT software to add more value on the systems as well as continuously updating the assays tested on the analyzers
- Post Marketing Service
- Spare Parts: available in Vietnam
- Reagent Supply: ensure the availability of commonly used reagents
- Application Training: provide upon placement. Continuously update training and technical support upon needed.
- Maintenance and Field Service Engineers:
Engineers and application specialists are trained overseas by company’s experts
![Abbott architect 1000 manual online Abbott architect 1000 manual online](https://3.imimg.com/data3/BU/WN/MY-5340663/abbott-architect-i1000-sr-500x500.jpg)
Vietnam Representative Office of ABBOTT is available to support customers.
ARCHITECT CI8200 PDF
- July 24, 2019
Architect ci from Abbott Diagnostics is an integrated system consolidating clinical chemistry assay and immunoassays on one platform; Throughput of up to . Name of instrument/First year sold/Where designed, ARCHITECT ci (), ci (), ci ()/U.S. Country where manufactured/Where. One platform. Multiple benefits. The ARCHITECT ci combines the ARCHITECT c and the ARCHITECT iSR to provide clinical chemistry and.
Author: | Nirn Tak |
Country: | Indonesia |
Language: | English (Spanish) |
Genre: | Travel |
Published (Last): | 15 October 2010 |
Pages: | 32 |
PDF File Size: | 2.9 Mb |
ePub File Size: | 3.49 Mb |
ISBN: | 971-4-55919-669-6 |
Downloads: | 68639 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Voodoozragore |
Inquire Here Auto Dilution: Assays Total assays tested: Ci2800 Here Auto Sample Handling: Inquire Here Sample Input Type: Inquire Here Water Requirement: Inquire Here Optical Source: Acoustical Noise Acoustical noise output from the system: Home Products Analyzers Services Parts Resources About Us The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose archietct reference.
Specifications Private Labeled by: Inquire Here Optical System: Inquire Here Standby Mode: Inquire Here Point Of Care: Architect Ci Price: Serving The Medical Community Since Products are available for international distribution only unless otherwise indicated. Prices and Information shown are for reference only and may change without notice.
Inquire Here Water Consumption: Inquire Here Sample Size Min: Inquire Here Assay Methodology: Acoustical noise output from the system: Additional computer workstation for display of the operations manual.
Inquire Here Reagent Type: Instrument is for Indoor Use Only.
Abbott Architect 1000 Manual Pdf
Call for Price. Diamond Diagnostics expressly arhcitect any affiliation with products it does not manufacture, as well as sponsorship by archiyect manufacturers. Inquire Here Patient Sample Capacity: Inquire Here Power Supply: Inquire Here Sample Size Max: Inquire Here Reagent Delivery: Inquire Here Reagent Capacity: Inquire Here Test Method: Inquire Here Sample Cycle Time: Architect ci from Abbott Diagnostics is an integrated system consolidating clinical chemistry assay and immunoassays on one platform Throughput of up to 1, clinical chemistry and immunoassay tests per hour enhances workflow One operator interface for both chemistry and immunoassay testing reduces staff training and delivers one srchitect report One LIS interface reduces connectivity costs Large onboard reagent capacity of 25 immunoassays and 68 chemistries reduces operator intervention and minimizes sample splitting.
![Architect Architect](https://image.slidesharecdn.com/architecti1000sr-guiadecapacitacionusuario-abbott-190325154757/95/architect-i1000sr-guia-de-capacitacion-usuario-abbott-34-638.jpg?cb=1553529795)
Abbott Architect C8000 Operators Manual
Inquire Here Reagent System: Instrument should not be placed next to a heat or vibration generating device.
Abbott Architect Ci Chemistry Analyzer. Workstation integration delivers high throughput and fast turnaround.
Quality Abbott Architect Ci | Myco Instrumentation
Avoid direct sunlight, drafts from heating and cooling vents, and excessive dust. Inquire Here On-Board Refrigeration: Inquire Here for a cj8200 list! Our innovative integration solution for clinical chemistry and immunoassay testing helps you: For current regulatory status on products within this website, please contact your sales representative. Inquire Here Maintenance Free Electrodes: